Basic data

Series46C

Functions

FunctionsActivation input

Characteristic parameters

Type2, IEC/EN 61496, in combination with a suitable test monitoring unit, e.g. MSI-TR1B
SIL1, IEC 61508, in combination with a suitable test monitoring unit, e.g. MSI-TR1B
SILCL1, IEC/EN 62061, in combination with a suitable test monitoring unit, e.g. MSI-TR1B
Performance Level (PL)c, EN ISO 13849-1:2008, In combination with MSI-TRMB safety relay
MTTFd400 years, EN ISO 13849-1
PFHD3E-10 per hour
Mission time20 years, EN ISO 13849-1
Category2, EN ISO 13849, In combination with a suitable test monitoring unit, e.g. MSI-TR1B

Optical data

Operating range0.5 ... 40 m
Operating range limit0.5 ... 48 m
Light sourceLED, Red
LED light wavelength630 nm
Transmitted-signal shapePulsed
LED group1
Opening angle, max.-5 ... 5 °

Electrical data

Protective circuitPolarity reversal protection, Short circuit protected

Performance data

Supply voltage UB24 V, DC, -20 ... 20 %, Incl. residual ripple
Residual ripple10 %, From UB
Open-circuit current0 ... 40 mA
Protective circuitPolarity reversal protection, Short circuit protected

Inputs

Number of activation inputs1 Piece(s)

Activation inputs

Voltage typeDC
Switching voltagehigh: ≥8V, low: ≤1.5V
Switching voltage high, min.8 V
Switching voltage low, max.1.5 V
Activation/disable delay1 ms
Input resistance10,000 Ω, -30 ... 30 %
Number of activation inputs1 Piece(s)

Activation input 1

Active switching stateHigh
Number of activation inputs1 Piece(s)
Protective circuitPolarity reversal protection, Short circuit protected

Timing

Switching frequency250 Hz
Response time2.5 ms
Readiness delay300 ms

Connection

Number of connections1 Piece(s)

Connection 1

Type of connectionCable
FunctionVoltage supply, Signal IN
Cable length