General specifications | |
---|---|
Detection type | photoelectric sampling |
Pulse count | 1024 |
Functional safety related parameters | |
MTTFd | 140 a |
Mission Time (TM) | 20 a |
L10h | 70 E+9 at 6000 rpm |
Diagnostic Coverage (DC) | 0 % |
Electrical specifications | |
Operating voltage | 10 ... 30 V DC |
No-load supply current | max. 60 mA |
Output | |
Output type | push-pull, incremental |
Voltage drop | < 3 V |
Load current | max. per channel 40 mA , short-circuit prtected (notwithUb), reverse polarity protected |
Output frequency | max. 200 kHz |
Rise time | 400 ns |
Connection | |
Connector | M12 connector, 8-pin |
Standard conformity | |
Degree of protection | DINEN60529, IP65 |
Climatic testing | DINEN60068-2-3, no moisture condensation |
Emitted interference | EN61000-6-4:2007/A1:2011 |
Noise immunity | EN61000-6-2:2005 |
Shock resistance | DINEN60068-2-27, 100g, 3ms |
Vibration resistance | DINEN60068-2-6, 10g, 10...2000Hz |
Approvals and certificates | |
UL approval | cULus Listed, General Purpose, Class 2 Power Source |
Ambient conditions | |
Operating temperature | |
Storage temperature | |
Mechanical specifications | |
Material | |
Mass | approx. 280 g |
Rotational speed | max. 12000 min -1 |
Moment of inertia | ? 35 gcm2 |
Starting torque | ? 1 Ncm |
Shaft load |